Go!
Menu
UL 325 2016
EMX Inc UL 325 2016
Miller Edge UL 325 2016
Loops & Detectors
BD Loops Preformed Loops
Direct Burial
Saw Cut
BEA Inc
Diablo Controls Inc
Doorking
EMX Inc
NorthStar
Reno A&E
Loop Supplies
Gate Operators
Gate Operator Manuals
Doorking
Parking Control / Barrier Gates
Swing Automatic Gate Operators
Slide Automatic Gate Operators
Liftmaster
NICE Apollo
OSCO/Linear/GTO Inc
Parking Control / Barrier Gates
Slide Gate Operators
Swing Gate Operators
Powermaster
Viking Access
Gate Operator Replacement Parts
Linear/OSCO
Gate Operator Controls
Albano
Control Stations and Key Switches
Key Switches
Push Buttons and Control Stations
Doorking
Access Control
Telephone Entry
EMX Inc
Linear
Transmitters and Receivers
Miller Edge
Omron
Carefree Security
Automatic Door Controls
BEA Inc
SENSORS
ELECTROMAGNETIC LOCKS
ELECTRIC STRIKES
SECURITY BUTTONS
PUSH PLATES
TOUCHLESS SENSORS
LOGIC MODULES
EMX Inc
Toggle navigation
DoorandGateMoving.com
UL 325 2016
EMX Inc UL 325 2016
Miller Edge UL 325 2016
Loops & Detectors
BD Loops Preformed Loops
Direct Burial
Saw Cut
BEA Inc
Diablo Controls Inc
Doorking
EMX Inc
NorthStar
Reno A&E
Loop Supplies
Gate Operators
Gate Operator Manuals
Doorking
Parking Control / Barrier Gates
Swing Automatic Gate Operators
Slide Automatic Gate Operators
Liftmaster
NICE Apollo
OSCO/Linear/GTO Inc
Parking Control / Barrier Gates
Slide Gate Operators
Swing Gate Operators
Powermaster
Viking Access
Gate Operator Replacement Parts
Linear/OSCO
Gate Operator Controls
Albano
Control Stations and Key Switches
Key Switches
Push Buttons and Control Stations
Doorking
Access Control
Telephone Entry
EMX Inc
Linear
Transmitters and Receivers
Miller Edge
Omron
Carefree Security
Automatic Door Controls
BEA Inc
SENSORS
ELECTROMAGNETIC LOCKS
ELECTRIC STRIKES
SECURITY BUTTONS
PUSH PLATES
TOUCHLESS SENSORS
LOGIC MODULES
EMX Inc
Home
>
Loops & Detectors
>
Diablo Controls Inc
>
DIABLO DSP-50, Plug-In Vehicle Detector
Our Price:
$
80.00
Product Code:
DSP-50
Qty:
Description
Technical Specs
DSP-50, Plug-In Vehicle Detector
Overview
The DSP-50 detector will add a new dimension of simplicity to your plug-in detector requirements as it can operate as a loop detector but with the flip of a switch it can operate our probe in pulse mode.
This detector operates on any voltage from 10 to 30 volts AC or DC.
It can be connected to a standard inductive loop or one of our new mini-loops. The Diablo Controls mini-Loop is a small “pipe shaped” device approximately 5” by 3/4” and is designed to be buried in the ground to detect vehicles.
The DSP-50 can be used as either a safety loop or free exit loop detector. With the flexibility to be either “fail safe” or “fail secure,” it is the most “user friendly” detector on the market today.
Ordering Information
Only one model available: DSP-50
Features
Works on any in-ground inductive loop from 20 to 2000 microhenries.
Can be connected to a standard inductive loop as well as the new mini-loops
Designed to be cross talk free between other loops
Automatically compensates for loop and lead-in sizes
Small profile, perfect for many installations
Fail safe operation
Wide low-voltage operation
Separate Power/Fail and Detect LEDs
LED Indicators: The green Power LED will be on steady to indicate the detector is operating and powered. In the case of a loop circuit or mini-loop failure, the green LED flashes slowly (twice per second) for an open loop circuit failure.
The green LED will flash fast (10 times per second) to indicate a shorted loop circuit.
The red Detect A LED will turn on when a vehicle is over the loop detection area. If delay is programmed, the LED will blink slowly during the delay interval. If extension is programmed, the LED will blink fast during the extension interval.
The red Detect B LED will echo the B output.
Sensitivity Switch: This detector has a 10-position rotary sensitivity switch. The unit is shipped in the “5” position which is the normal sensitivity level.
Sensitivity can be adjusted up and down from this level to accommodate different street loops or mini-loops.
Frequency: One of four operating frequencies can be selected by changing DIP switches 9 and 10
Loop Type: Turn DIP switch 8 off to operate with a normal inductive loop. Turn the switch on to operate with a Diablo Controls mini-loop.
Extended Presence Time: Turn DIP switch 7 off to hold a vehicle’s presence for about 20 minutes before tuning it out. Turn the switch on to hold it much longer.
Output B Control:
DIP Switches 6 and 5 (Effects output “B” only)
6 = OFF and 5 = OFF B output is normal presence output.
6 = OFF and 5 = ON B output is an “Entry“ pulse.
6 = ON and 5 = OFF B output is an “Exit” pulse.
6 = ON and 5 = ON B output is a “Fail” condition.
Sensitivity Boost: Turn DIP switch 4 off to operate with normal sensitivity. Turn DIP switch 4 on to automatically boost sensitivity during a call to improve detection of high-bed vehicles and truck/trailer combinations.
Sensitivity boost is not applicable to most situations.
Failure Operation: A fail safe detector will output “detect” when the loop circuit is failed. This is always useful on a safety loop. On the free exit loop this will keep the gate open until the situation is fixed.
This is useful in applications where it is important to allow traffic flow to continue. A fail secure detector will never output “detect” when the loop circuit is failed. This will keep the gate closed.
This is useful in high-security areas or installations where containment is needed. Turn DIP switch 3 off to operate in fail safe mode. Turn the switch on to operate in fail secure.
Note: Never use a fail secure detector on a safety loop.
Output A Control
DIP Switches 1 and 2 (Effects output “A” only)
1 = OFF and 2 = OFF Output A normal Presence.
1 = OFF and 2 = ON Output A has 2 seconds of delay.
1 = ON and 2 = OFF Output A has 2 seconds of extension.
1 = ON and 2 = ON Output A has 5 seconds of extension.
Mini-Loop Operation: The mini-loop mode will always be an entry pulse. As such, it is perfect for free exit operation. Never use the mini-loop as a safety loop.
Outputs: Solid-state (open transistor collectors) for both detect” and fail outputs. 30 mA maximum current sink - transient voltage protected.
Power: 12 to 30 volts DC
Operating Temperature: -35°F to 165°F (-37°C to 74°C)
Enclosure: Impact resistant, high temperature plastic.
H: 2.375” (60.4 mm) W: 0.86” (22 mm) L: 2.25 ” (58mm)
Connector: (looking into the connector – right to left.)
1 Loop or Mini-Loop
2 Loop or Mini-Loop
3 Power input “+”
4 Not Connected
5 Not Connected
6 Output B
7 Output B reversed
8 Output A
9 Power input “+”
10 Power (and logic) common
Related Items
DIABLO DSP-22S-1 Series, Vehicle Detector
DIABLO DSP-40S, Plug-In Vehicle Detector
Loop Detector 11 Pin harness
DIABLO DSP-15-LV, Vehicle Detector
Our Price:
$91.00
Our Price:
$82.00
Our Price:
$11.00
Our Price:
$89.00
DIABLO DSP-20-11-LV, Dual Channel Vehicle Detector
DIABLO DSP-10-LV Series, Vehicle Detector
DIABLO DSP-50, Mini Loop Kit, 75'
DIABLO DLD-2, Directional Logic Device
Our Price:
$135.00
Our Price:
$90.00
Our Price:
$160.00
Our Price:
$79.81
Share your knowledge of this product.
Be the first to write a review »
Company
Privacy Policy
Terms & Conditions
Product Index
Category List
Customers
FAQ/Help
Shipping & Deliveries
Returns & Exchanges
Account
My Account
Login
/
Register
Order Status
Connect
Facebook
Twitter
Copyright ©
2014
DoorandGateMoving.com. All Rights Reserved.
Built with
Volusion
.